{"product_id":"semikron-danfoss-skkt-570-16-e-dual-thyristor-module","title":"Semikron Danfoss SKKT 570\/16 E Dual Thyristor Module","description":"\u003cdiv class=\"productDescription\"\u003e\n\u003cp data-start=\"167\" data-end=\"482\"\u003eThe \u003cstrong data-start=\"171\" data-end=\"205\"\u003eSemikron Danfoss SKKT 570\/16 E\u003c\/strong\u003e is a \u003cstrong data-start=\"211\" data-end=\"259\"\u003ehigh-reliability dual thyristor (SCR) module\u003c\/strong\u003e designed for demanding \u003cstrong data-start=\"283\" data-end=\"331\"\u003epower control and rectification applications\u003c\/strong\u003e. Built using \u003cstrong data-start=\"345\" data-end=\"370\"\u003eSEMIPACK 5 technology\u003c\/strong\u003e, it integrates two thyristors in a compact, electrically isolated package for efficient and robust performance.\u003c\/p\u003e\n\u003cp data-start=\"484\" data-end=\"845\"\u003eEngineered for \u003cstrong data-start=\"499\" data-end=\"547\"\u003ehigh current (570A) and high voltage (1600V)\u003c\/strong\u003e operation, this module is widely used in \u003cstrong data-start=\"589\" data-end=\"669\"\u003emotor drives, soft starters, industrial rectifiers, and AC power controllers\u003c\/strong\u003e. Its advanced design ensures \u003cstrong data-start=\"699\" data-end=\"804\"\u003eexcellent thermal performance, high surge capability, and long-term reliability in harsh environments\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1vbta0f\" data-start=\"852\" data-end=\"872\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"873\" data-end=\"1784\"\u003e\n\u003cli data-section-id=\"1s4ia3k\" data-start=\"873\" data-end=\"991\"\u003e\n\u003cstrong data-start=\"875\" data-end=\"913\"\u003eDual thyristor (SCR) configuration\u003c\/strong\u003e – compact and efficient power control \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1yso9vz\" data-start=\"992\" data-end=\"1102\"\u003e\n\u003cstrong data-start=\"994\" data-end=\"1024\"\u003eHigh current rating (570A)\u003c\/strong\u003e – suitable for heavy industrial loads \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1w898zc\" data-start=\"1103\" data-end=\"1214\"\u003e\n\u003cstrong data-start=\"1105\" data-end=\"1140\"\u003eHigh voltage capability (1600V)\u003c\/strong\u003e – supports demanding applications \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"c01exn\" data-start=\"1215\" data-end=\"1313\"\u003e\n\u003cstrong data-start=\"1217\" data-end=\"1239\"\u003eSEMIPACK 5 housing\u003c\/strong\u003e – industry-proven module platform \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"18774j7\" data-start=\"1314\" data-end=\"1450\"\u003e\n\u003cstrong data-start=\"1316\" data-end=\"1352\"\u003eIsolated baseplate (AlN ceramic)\u003c\/strong\u003e – excellent thermal conductivity and electrical isolation \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"rm1dal\" data-start=\"1451\" data-end=\"1564\"\u003e\n\u003cstrong data-start=\"1453\" data-end=\"1498\"\u003eHigh surge current capability (~15–19 kA)\u003c\/strong\u003e – handles transient loads \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ohqrtk\" data-start=\"1565\" data-end=\"1679\"\u003e\n\u003cstrong data-start=\"1567\" data-end=\"1603\"\u003eAmplifying gate thyristor design\u003c\/strong\u003e – reliable triggering and switching \u003cspan class=\"\" data-state=\"instant-open\" aria-describedby=\"radix-_r_17e_\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"knoq5x\" data-start=\"1680\" data-end=\"1784\"\u003e\n\u003cstrong data-start=\"1682\" data-end=\"1709\"\u003eUL recognized component\u003c\/strong\u003e – compliant for industrial systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"lewz3c\" data-start=\"1973\" data-end=\"1989\"\u003eElectrical\u003c\/h3\u003e\n\u003cul data-start=\"1991\" data-end=\"2507\"\u003e\n\u003cli data-section-id=\"lo364m\" data-start=\"1991\" data-end=\"2077\"\u003e\n\u003cstrong data-start=\"1993\" data-end=\"2029\"\u003eAverage On-State Current (ITAV):\u003c\/strong\u003e 570 A \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1l5i7yi\" data-start=\"2078\" data-end=\"2169\"\u003e\n\u003cstrong data-start=\"2080\" data-end=\"2120\"\u003eRepetitive Peak Voltage (VDRM\/VRRM):\u003c\/strong\u003e 1600 V \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"4zag7\" data-start=\"2170\" data-end=\"2255\"\u003e\n\u003cstrong data-start=\"2172\" data-end=\"2197\"\u003eSurge Current (ITSM):\u003c\/strong\u003e up to ~15–19 kA \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"15h0xeh\" data-start=\"2256\" data-end=\"2338\"\u003e\n\u003cstrong data-start=\"2258\" data-end=\"2284\"\u003eOn-State Voltage (VT):\u003c\/strong\u003e ~1.4–1.65 V \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"12atgdx\" data-start=\"2339\" data-end=\"2426\"\u003e\n\u003cstrong data-start=\"2341\" data-end=\"2372\"\u003eGate Trigger Current (IGT):\u003c\/strong\u003e ~150–200 mA \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"nxyknx\" data-start=\"2427\" data-end=\"2507\"\u003e\n\u003cstrong data-start=\"2429\" data-end=\"2460\"\u003eGate Trigger Voltage (VGT):\u003c\/strong\u003e ~3 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"2ayq5\" data-start=\"2514\" data-end=\"2530\"\u003eMechanical\u003c\/h3\u003e\n\u003cul data-start=\"2532\" data-end=\"2889\"\u003e\n\u003cli data-section-id=\"1m6gdhm\" data-start=\"2532\" data-end=\"2606\"\u003e\n\u003cstrong data-start=\"2534\" data-end=\"2546\"\u003eHousing:\u003c\/strong\u003e SEMIPACK 5 module \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"avlvbn\" data-start=\"2607\" data-end=\"2695\"\u003e\n\u003cstrong data-start=\"2609\" data-end=\"2624\"\u003eDimensions:\u003c\/strong\u003e approx. \u003cstrong data-start=\"2633\" data-end=\"2653\"\u003e150 × 60 × 52 mm\u003c\/strong\u003e \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"du1bdj\" data-start=\"2696\" data-end=\"2737\"\u003e\n\u003cstrong data-start=\"2698\" data-end=\"2711\"\u003eMounting:\u003c\/strong\u003e Screw-mounted baseplate\u003c\/li\u003e\n\u003cli data-section-id=\"1pf3ocj\" data-start=\"2738\" data-end=\"2823\"\u003e\n\u003cstrong data-start=\"2740\" data-end=\"2754\"\u003eTerminals:\u003c\/strong\u003e Faston \/ screw connections \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"10kgs20\" data-start=\"2824\" data-end=\"2889\"\u003e\n\u003cstrong data-start=\"2826\" data-end=\"2840\"\u003ePin Count:\u003c\/strong\u003e 7 pins \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"dn9afn\" data-start=\"2896\" data-end=\"2925\"\u003eThermal \u0026amp; Environmental\u003c\/h3\u003e\n\u003cul data-start=\"2927\" data-end=\"3176\"\u003e\n\u003cli data-section-id=\"1xfo9xx\" data-start=\"2927\" data-end=\"3012\"\u003e\n\u003cstrong data-start=\"2929\" data-end=\"2959\"\u003eMax Operating Temperature:\u003c\/strong\u003e ~125–135°C \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"pjc5nt\" data-start=\"3013\" data-end=\"3127\"\u003e\n\u003cstrong data-start=\"3015\" data-end=\"3039\"\u003eIsolation Baseplate:\u003c\/strong\u003e Aluminum nitride ceramic for heat dissipation \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"11te7b1\" data-start=\"3128\" data-end=\"3176\"\u003e\n\u003cstrong data-start=\"3130\" data-end=\"3142\"\u003eCooling:\u003c\/strong\u003e Heatsink required for operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"APSS Store","offers":[{"title":"Default Title","offer_id":52011768971567,"sku":"APSS-ITEM-00018962","price":242.73,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0835\/5826\/9231\/files\/BC_Upload_d0c05b2c-3da4-49f7-9fcd-41b110c60591.png?v=1763005561","url":"https:\/\/onlinestore.apss.com\/products\/semikron-danfoss-skkt-570-16-e-dual-thyristor-module","provider":"APSS Store","version":"1.0","type":"link"}