{"product_id":"006824-001","title":"006824-001","description":"\u003cdiv class=\"productDescription\"\u003e\u003cspan\u003eDet-tronics CGS Catalytic Combustible Gas Sensor for UD10, UD30, DCUEX, U9500A, U8700, K-Series, 400, 405, 505, 500, 810, 820, and 880 Transmitters. Stainless steel catalytic sensor with %LEL range. FM, CSA, ATEX, IECEx, Brazilian and SIL 2 Approvals.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"productDescription\"\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"productDescription\"\u003e\u003cb\u003eDESCRIPTION\u003c\/b\u003e\u003c\/div\u003e\n\u003cdiv class=\"productDescription\"\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/div\u003e\n\u003cdiv class=\"productDescription\"\u003e\n\u003cp\u003eThe heart of the catalytic sensor consists of a pair of computer matched pellistors (beads) that provide identical electrical resistance in clean air. When flammable gas is present, the active bead catalyzes the combustible gas molecules, while the inactive (reference) bead balances the reaction and compensates for normal changes in the ambient environment. The sophisticated design and construction of Det-Tronics catalytic sensors provides excellent sensitivity, response time, and resistance to physical shock and vibration.\u003c\/p\u003e\n\u003cp\u003eAll Det-Tronics catalytic gas sensors are poison-resistant, and are constructed with a one-piece 316 stainless steel housing. Other features include an integral thermal barrier to prevent bead interaction, and a sinter bonding technique to ensure superior protection against electromagnetic interference. All sensors are provided with a laser etched identification and approvals label that will withstand exposure to harsh outdoor industrial environments.\u003c\/p\u003e\n\u003cp\u003eThe CGS can be used for detection of virtually all combustible and flammable gases, including hydrogen, and is compatible with the FlexVu ® UD10, Infiniti® U9500, Model 505 transmitter, EQ22xxDCUEX, and STB.\u003c\/p\u003e\n\u003cspan\u003e\u003cb\u003eFEATURES AND BENEFITS\u003c\/b\u003e\u003c\/span\u003e\n\u003cul class=\"uList\"\u003e\n\u003cli\u003eOne piece design with integral thermal barrier\u003c\/li\u003e\n\u003cli\u003eSinter bonded flame arrestor provides superior EMI protection\u003c\/li\u003e\n\u003cli\u003e316 stainless steel housing\u003c\/li\u003e\n\u003cli\u003eExcellent impact and vibration resistance\u003c\/li\u003e\n\u003cli\u003eStandard poison-resistant performance rating\u003c\/li\u003e\n\u003cli\u003eFM\/CSA\/ATEX\/IECEx\/Brazilian Approvals\u003c\/li\u003e\n\u003cli\u003eCompatible with all Det-Tronics combustible gas transmitters and controllers\u003c\/li\u003e\n\u003cli\u003eSensor Separation Termination Box (STB) options available\u003c\/li\u003e\n\u003cli\u003eExtended operating temperature range\u003c\/li\u003e\n\u003cli\u003eComprehensive list of conversion K factors for proper calibration available\u003c\/li\u003e\n\u003cli\u003e3\/4 inch NPT, 20 mm, or 25 mm thread types\u003c\/li\u003e\n\u003cli\u003eSix inch or optional 30 inch wire lead lengths\u003c\/li\u003e\n\u003cli\u003eConstant voltage or constant current sensor types available\u003c\/li\u003e\n\u003cli\u003eSIL2 certified to IEC6\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable width=\"495\" cellpadding=\"2\" cellspacing=\"2\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"SpecName\" colspan=\"2\" style=\"width: 538.881px;\"\u003e\u003cstrong\u003eSPECIFICATIONS\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"SpecName\" style=\"width: 132.016px;\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd class=\"specDescription\" style=\"width: 406.865px;\"\u003eOperating: –67°F to +257°F (–55°C to +125°C).\u003cbr\u003ePerformance: –40°F to +167°F (–40°C to +75°C).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"SpecName\" style=\"width: 132.016px;\"\u003eHumidity Range\u003c\/td\u003e\n\u003ctd class=\"specDescription\" style=\"width: 406.865px;\"\u003e0 to 99% RH, non-condensing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"SpecName\" style=\"width: 132.016px;\"\u003eResponse Time\u003c\/td\u003e\n\u003ctd class=\"specDescription\" style=\"width: 406.865px;\"\u003eT50, s: \u0026lt;10\u003cbr\u003eT90, s: \u0026lt;30\u003cbr\u003eVerification: FM, CSA, ATEX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"SpecName\" style=\"width: 132.016px;\"\u003eRecovery Time\u003c\/td\u003e\n\u003ctd class=\"specDescription\" style=\"width: 406.865px;\"\u003e\u0026lt; 30 seconds after exposure to pure methane.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"SpecName\" style=\"width: 132.016px;\"\u003eAccuracy \/ Linearity\u003c\/td\u003e\n\u003ctd class=\"specDescription\" style=\"width: 406.865px;\"\u003e±3% LFL from 0 to 50% LFL,\u003cbr\u003e±5% LFL from 51% to 100% LFL.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"SpecName\" style=\"width: 132.016px;\"\u003eWiring\u003c\/td\u003e\n\u003ctd class=\"specDescription\" style=\"width: 406.865px;\"\u003e2x22 AWG, 1x16 AWG, 600V, 20\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"SpecName\" style=\"width: 132.016px;\"\u003eRepeatability\u003c\/td\u003e\n\u003ctd class=\"specDescription\" style=\"width: 406.865px;\"\u003e±1% LFL.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"SpecName\" style=\"width: 132.016px;\"\u003eLong Term Stability\u003c\/td\u003e\n\u003ctd class=\"specDescription\" style=\"width: 406.865px;\"\u003eZero: \u0026lt; 1% LFL per month.\u003cbr\u003eSpan: \u0026lt; 1% LFL per month in clean air.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"SpecName\" style=\"width: 132.016px;\"\u003eTemperature Stability\u003c\/td\u003e\n\u003ctd class=\"specDescription\" style=\"width: 406.865px;\"\u003e\u0026lt; ±5% LFL: –13°F to +167°F (–25°C to +75°C).\u003cbr\u003e\u0026lt; ±10% LFL: –40°F to –13°F (–40°C to –25°C).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"SpecName\" style=\"width: 132.016px;\"\u003eSensor Life\u003c\/td\u003e\n\u003ctd class=\"specDescription\" style=\"width: 406.865px;\"\u003e3 to 5 years, when environment is free of substances and conditions known to be detrimental to catalytic sensing elements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"SpecName\" style=\"width: 132.016px;\"\u003eStorage Life\u003c\/td\u003e\n\u003ctd class=\"specDescription\" style=\"width: 406.865px;\"\u003eIndefinite, when stored in unopened original packaging.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"SpecName\" style=\"width: 132.016px;\"\u003eCalibration Cycle\u003c\/td\u003e\n\u003ctd class=\"specDescription\" style=\"width: 406.865px;\"\u003e30 days after initial calibration and every 90 days thereafter, or as required by the application and environment.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"SpecName\" style=\"width: 132.016px;\"\u003eRFI\/EMI Immunity\u003c\/td\u003e\n\u003ctd class=\"specDescription\" style=\"width: 406.865px;\"\u003eRefer to selected transmitter specification.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"SpecName\" style=\"width: 132.016px;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd class=\"specDescription\" style=\"width: 406.865px;\"\u003e1.5in (3.8cm) x 1.7in (4.4cm) x 2.0in (5.2cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"SpecName\" style=\"width: 132.016px;\"\u003eThread options\u003c\/td\u003e\n\u003ctd class=\"specDescription\" style=\"width: 406.865px;\"\u003e• 3\/4” NPT\u003cbr\u003e• M20\u003cbr\u003e• M25.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"SpecName\" style=\"width: 132.016px;\"\u003eCertification\u003c\/td\u003e\n\u003ctd class=\"specDescription\" style=\"width: 406.865px;\"\u003eFM\/CSA:\u003cbr\u003eClass I, Div. 1, Groups B, C, \u0026amp; D\u003cbr\u003eTamb = –40°C to +75°C\u003cbr\u003eExplosion-proof verified:\u003cbr\u003e–40°F to +257°F (–40°C to +125°C)\u003cbr\u003ePerformance verified:\u003cbr\u003e–40°F to +167°F (–40°C to +75°C)\u003cbr\u003eComplies with ANSI\/ISA-12.13.01-2000.\u003cbr\u003eATEX:\u003cbr\u003eCE 0539\u003cbr\u003eII 2 G\u003cbr\u003eEx db IIC T3\/T5\u003cbr\u003eDEMKO 02 ATEX 131323X\u003cbr\u003eT5 (Tamb = –40°C to +75°C)\u003cbr\u003eT3 (Tamb = –55°C to +125°C)\u003cbr\u003eIECEx:\u003cbr\u003eEx db IIC T3\/T5\u003cbr\u003eIECEx ULD 10.0001X\u003cbr\u003eT5 (Tamb = –40°C to +75°C)\u003cbr\u003eT3 (Tamb = –55°C to +125°C)\u003cbr\u003eEN\/IEC Standards:\u003cbr\u003eEN\/IEC 60079-0: 2012\/2011\u003cbr\u003eEN\/IEC 60079-1: 2014\u003cbr\u003eEN 60079-29-1: 2007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"APSS Store","offers":[{"title":"Default Title","offer_id":51954610602287,"sku":"APSS-ITEM-00016828","price":757.56,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0835\/5826\/9231\/files\/DC-006824001.jpg?v=1761621787","url":"https:\/\/onlinestore.apss.com\/vi\/products\/006824-001","provider":"APSS Store","version":"1.0","type":"link"}