{"product_id":"ultramat-23-rack-device-1-channel","title":"ULTRAMAT 23, Rack Device, 1 Channel","description":"\u003ch1\u003eULTRAMAT 23, Rack Device, 1 Channel\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong data-start=\"278\" data-end=\"301\"\u003eSiemens ULTRAMAT 23\u003c\/strong\u003e is a high-precision \u003cstrong data-start=\"322\" data-end=\"349\"\u003eextractive gas analyzer\u003c\/strong\u003e designed for continuous measurement of infrared (IR)-absorbing gases. Built in a \u003cstrong data-start=\"431\" data-end=\"458\"\u003e19” rack-mounted format\u003c\/strong\u003e, it supports reliable monitoring in industrial, environmental, and process control applications.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1ibzexv\" data-start=\"602\" data-end=\"620\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"621\" data-end=\"1255\"\u003e\n\u003cli data-section-id=\"1m662fd\" data-start=\"621\" data-end=\"745\"\u003e\n\u003cstrong data-start=\"623\" data-end=\"668\"\u003eNDIR (Non-Dispersive Infrared) technology\u003c\/strong\u003e for high selectivity gas measurement \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"w3zndp\" data-start=\"746\" data-end=\"803\"\u003e\n\u003cstrong data-start=\"748\" data-end=\"775\"\u003e1-channel configuration\u003c\/strong\u003e (single IR gas component)\u003c\/li\u003e\n\u003cli data-section-id=\"m5hvrf\" data-start=\"804\" data-end=\"862\"\u003eOptional \u003cstrong data-start=\"815\" data-end=\"860\"\u003eO₂ measurement via electrochemical sensor\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1rhptwi\" data-start=\"863\" data-end=\"974\"\u003e\n\u003cstrong data-start=\"865\" data-end=\"885\"\u003eAUTOCAL function\u003c\/strong\u003e using ambient air (reduced calibration gas need) \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"4d120i\" data-start=\"975\" data-end=\"1084\"\u003eLow cross-sensitivity (e.g., minimal interference from water vapor) \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"k4wusf\" data-start=\"1085\" data-end=\"1144\"\u003eRobust, \u003cstrong data-start=\"1095\" data-end=\"1124\"\u003ecleanable measuring cells\u003c\/strong\u003e for long-term use\u003c\/li\u003e\n\u003cli data-section-id=\"eh7os0\" data-start=\"1145\" data-end=\"1200\"\u003eMenu-guided operation with \u003cstrong data-start=\"1174\" data-end=\"1198\"\u003eplain-text interface\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1rohdwm\" data-start=\"1201\" data-end=\"1255\"\u003eIntegrated \u003cstrong data-start=\"1214\" data-end=\"1255\"\u003elogbook for diagnostics \u0026amp; maintenance\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1j7sgdk\" data-start=\"1262\" data-end=\"1287\"\u003eMechanical \u0026amp; Design\u003c\/h3\u003e\n\u003cul data-start=\"1288\" data-end=\"1680\"\u003e\n\u003cli data-section-id=\"1lj980v\" data-start=\"1288\" data-end=\"1377\"\u003e\n\u003cstrong data-start=\"1290\" data-end=\"1302\"\u003eMounting\u003c\/strong\u003e: 19-inch rack device (4 HU height) \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ocn5u9\" data-start=\"1378\" data-end=\"1431\"\u003e\n\u003cstrong data-start=\"1380\" data-end=\"1396\"\u003eInstallation\u003c\/strong\u003e: Cabinet or swing frame mounting\u003c\/li\u003e\n\u003cli data-section-id=\"9v6lse\" data-start=\"1432\" data-end=\"1560\"\u003e\n\u003cstrong data-start=\"1434\" data-end=\"1453\"\u003eGas connections\u003c\/strong\u003e:\n\u003cul data-start=\"1459\" data-end=\"1560\"\u003e\n\u003cli data-section-id=\"x3lb4k\" data-start=\"1459\" data-end=\"1488\"\u003eSample gas inlet \u0026amp; outlet\u003c\/li\u003e\n\u003cli data-section-id=\"1yv6l94\" data-start=\"1491\" data-end=\"1560\"\u003ePipe diameter: 6 mm or 1\/4” \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"xrvcb6\" data-start=\"1561\" data-end=\"1625\"\u003e\n\u003cstrong data-start=\"1563\" data-end=\"1578\"\u003eFront panel\u003c\/strong\u003e:\n\u003cul data-start=\"1584\" data-end=\"1625\"\u003e\n\u003cli data-section-id=\"18uff2w\" data-start=\"1584\" data-end=\"1625\"\u003eFlowmeter (optional pump integration)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1kptqxr\" data-start=\"1626\" data-end=\"1680\"\u003e\n\u003cstrong data-start=\"1628\" data-end=\"1642\"\u003eRear panel\u003c\/strong\u003e:\n\u003cul data-start=\"1648\" data-end=\"1680\"\u003e\n\u003cli data-section-id=\"2ax32o\" data-start=\"1648\" data-end=\"1680\"\u003eElectrical \u0026amp; gas connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-section-id=\"ean3rh\" data-start=\"1687\" data-end=\"1717\"\u003eMeasurement Capabilities\u003c\/h4\u003e\n\u003cul data-start=\"1718\" data-end=\"2058\"\u003e\n\u003cli data-section-id=\"17yhwg\" data-start=\"1718\" data-end=\"1781\"\u003e\n\u003cstrong data-start=\"1720\" data-end=\"1732\"\u003eChannels\u003c\/strong\u003e: 1 IR component (expandable in other versions)\u003c\/li\u003e\n\u003cli data-section-id=\"oex2dx\" data-start=\"1782\" data-end=\"1927\"\u003e\n\u003cstrong data-start=\"1784\" data-end=\"1804\"\u003eDetectable gases\u003c\/strong\u003e (depending on configuration):\n\u003cul data-start=\"1839\" data-end=\"1927\"\u003e\n\u003cli data-section-id=\"rezjl4\" data-start=\"1839\" data-end=\"1927\"\u003eCO, CO₂, NO, SO₂, CH₄, refrigerants (e.g. R22) \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ni8xfy\" data-start=\"1928\" data-end=\"2058\"\u003eOptional:\n\u003cul data-start=\"1942\" data-end=\"2058\"\u003e\n\u003cli data-section-id=\"plquo\" data-start=\"1942\" data-end=\"1977\"\u003e\u003cstrong data-start=\"1944\" data-end=\"1975\"\u003eO₂ (electrochemical sensor)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1w2z55u\" data-start=\"1980\" data-end=\"2058\"\u003e\n\u003cstrong data-start=\"1982\" data-end=\"1996\"\u003eH₂S sensor\u003c\/strong\u003e (in extended configs)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-section-id=\"1hcpicb\" data-start=\"2378\" data-end=\"2400\"\u003eInputs \u0026amp; Outputs\u003c\/h4\u003e\n\u003cul data-start=\"2401\" data-end=\"2746\"\u003e\n\u003cli data-section-id=\"kyx8np\" data-start=\"2401\" data-end=\"2501\"\u003e\n\u003cstrong data-start=\"2403\" data-end=\"2421\"\u003eAnalog outputs\u003c\/strong\u003e: Electrically isolated (e.g. 4–20 mA) \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"12ypadl\" data-start=\"2502\" data-end=\"2612\"\u003e\n\u003cstrong data-start=\"2504\" data-end=\"2521\"\u003eBinary inputs\u003c\/strong\u003e (standard):\n\u003cul data-start=\"2536\" data-end=\"2612\"\u003e\n\u003cli data-section-id=\"1w96ymv\" data-start=\"2536\" data-end=\"2561\"\u003ePump control (On\/Off)\u003c\/li\u003e\n\u003cli data-section-id=\"103yglt\" data-start=\"2564\" data-end=\"2583\"\u003eAUTOCAL trigger\u003c\/li\u003e\n\u003cli data-section-id=\"83cs5e\" data-start=\"2586\" data-end=\"2612\"\u003eDevice synchronization\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1o1qarb\" data-start=\"2613\" data-end=\"2700\"\u003e\n\u003cstrong data-start=\"2615\" data-end=\"2632\"\u003eRelay outputs\u003c\/strong\u003e:\n\u003cul data-start=\"2636\" data-end=\"2700\"\u003e\n\u003cli data-section-id=\"1pssqvw\" data-start=\"2636\" data-end=\"2652\"\u003eFault signal\u003c\/li\u003e\n\u003cli data-section-id=\"17liig8\" data-start=\"2655\" data-end=\"2677\"\u003eMaintenance alerts\u003c\/li\u003e\n\u003cli data-section-id=\"kov3dd\" data-start=\"2680\" data-end=\"2700\"\u003eLimit monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"fxae5u\" data-start=\"2701\" data-end=\"2746\"\u003eExpandable I\/O (optional modules available)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"APSS Store","offers":[{"title":"Default Title","offer_id":51930039288111,"sku":null,"price":20160.0,"currency_code":"SGD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0835\/5826\/9231\/files\/Screenshot2025-10-15153431.png?v=1760513685","url":"https:\/\/onlinestore.apss.com\/vi\/products\/ultramat-23-rack-device-1-channel","provider":"APSS Store","version":"1.0","type":"link"}