General data
| Standards |
DIN VDE 0660-208 EN IEC 60947-5-2 |
| Housing construction form |
Cylinder, thread |
| Installation conditions (mechanical) |
flush |
| Housing material |
Brass |
| Housing coating material |
nickel-plated |
| Active area |
Plastic |
| Material of the nuts |
Brass |
| Gross weight |
69 g |
Connection technique
| Length of cable |
2 m |
| Termination |
Cable |
| Wire cross-section |
0.14 mm2 |
| Material of the Cable mantle |
PVC |
Dimensions
| ISO thread of the sensor |
M8 |
| width across flats |
13 BK |
| Length of sensor |
42 mm |
Ambient conditions
| Degree of protection |
IP67 |
| Ambient temperature |
-25 ... +70 °C |
| Resistance to vibrations |
10 … 55 Hz, amplitude 1 mm |
| Restistance to shock |
30 g / 11 ms |
| Protection class |
0 |
Electrical data
| Type of voltage range |
DC |
| No-load supply current I0, typical |
3.4 mA |
| Rated operating voltage |
10 ... 30 VDC |
| Operating current |
200 mA |
| Switching element |
Normally open contact (NO) |
| Protection circuit integrated |
inductive interference protection Protection against polarity reversal Surge protection Max. fuse rating |
| Switching frequency, approx. |
3,000 Hz |