Specifications
Range | TeSys |
---|---|
Product Name | TeSys F |
Product or component type | Contactor |
Device short name | LC1F |
Contactor application | Motor control Resistive load |
Utilisation category | AC-4 AC-3 AC-1 |
Polishing description | Threesome |
Power Pole Contact Composition | 3 NO |
[Ue] rated operational voltage | <= 1000 V AC 50/60 Hz <= 460 V DC |
[Ie] rated operational current | 400 A (at <40 °C) at <= 440 V AC AC-1 330 A (at <55 °C) at <= 440 V AC AC-3 |
Motor power kW | 160 kW at 1000 V AC 50/60 Hz (AC-3) 160 kW at 380...400 V AC 50/60 Hz (AC-3) 180 kW at 415 V AC 50/60 Hz (AC-3) 200 kW at 440 V AC 50/60 Hz (AC-3) 200 kW at 500 V AC 50/60 Hz (AC-3) 100 kW at 220...240 V AC 50/60 Hz (AC-3) 220 kW at 660...690 V AC 50/60 Hz (AC-3) 59 kW at 400 V AC 50/60 Hz (AC-4) |
Complementary
[Uc] control circuit voltage | 24...1000 V AC 40...400 Hz with LX1/LX9 coil 24...460 V DC with LX4 coil 100...250 V AC 50/60 Hz with LXE coil 100...380 V DC with LXE coil |
---|---|
[Uimp] rated impulse withstand voltage | 8 kV |
Overvoltage category | III |
[Ith] conventional free air thermal current | 400 A (at 40 °C) |
Irms rated making capacity | 3300 A AC conforming to IEC 60947-4-1 |
Rated breaking capacity | 2640 A conforming to IEC 60947-4-1 |
[Icw] rated short-time withstand current | 2650 A 40 °C - 10 s 1800 A 40 °C - 30 s 1300 A 40 °C - 1 min 900 A 40 °C - 3 min 750 A 40 °C - 10 min |
Associated fuse rating | 400 A aM at <= 440 V 500 A gG at <= 440 V |
Average impedance | 0.28 mOhm – Ith 400 A 50 Hz |
[Ui] rated insulation voltage | 1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C |
Power dissipation per pole | 44 W AC-1 31 W AC-3 |
Control circuit voltage limits | Operational: 0.85...1.1 Uc AC 40...400 Hz with LX1/LX9 coil Drop-out: 0.35...0.55 Uc AC 40...400 Hz with LX1/LX9 coil Operational: 0.85...1.1 Uc DC with LX4 coil Drop-out: 0.15...0.2 Uc DC with LX4 coil Operational: 85...275 V AC 50/60 Hz with LXE coil Drop-out: 0...60 V AC 50/60 Hz with LXE coil Operational: 85...418 V DC with LXE coil Drop-out: 0...45 V DC with LXE coil |
Heat dissipation | 8 W 2.2... 5.5 W |
Operating time | 40...65 ms closing for with LX1/LX9 coil 100...170 ms opening for with LX1/LX9 coil 40...50 ms closing for with LX4 coil 40...65 ms opening for with LX4 coil 40...80 ms closing for with LXE coil 6...54 ms opening for with LXE coil |
Mounting support | Plate |
Standards | IEC 60947-4-1 JIS C8201-4-1 EN 60947-1 IEC 60947-1 EN 60947-4-1 |
Product certifications | ABS CSA UL RMRoS DNV CB BV LROS (Lloyds register of shipping) RINA UKCA |
Connections - terminals | Power circuit: lugs-ring terminals 1 cable(s) 240 mmPower circuit: bar 2 cable(s) - busbar cross section: 30 x 5 mm Control circuit: screw clamp terminals 1 cable(s) 1... 4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1... 4 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1... 4 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1... 2.5 mm²solid without cable end Control circuit: screw clamp terminals 1 cable(s) 1... 4 mm² Control circuit: screw clamp terminals 2 cable(s) 1... 4 mm² Control circuit: screw clamp terminals 1.0 cable(s) 0.2... 2.5 mm²flexible without cable end Control circuit: screw clamp terminals 1.0 cable(s) 0.25... 2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1.0 cable(s) 0.2... 2.5 mm²solid without cable end |
Tightening torque | Power circuit: 35 N.m Control circuit: 1.2 N.m Control circuit: 0.6 N.m |
Mechanical durability | 10 Mcycles |
Inrush power in VA | 600… 700 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil 655... 803 VA (at 20 °C)with LX4 coil 300... 350 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil 300... 310 VA (at 20 °C)with LXE coil |
Hold-in power consumption in VA | 8… 10 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX1/LX9 coil 3.68... 4.53 VA (at 20 °C)with LX4 coil 4.5... 7.0 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil 2.5... 4.0 VA (at 20 °C)with LXE coil |
Maximum operating rate | 2400 cyc/h 55 °C |
Compatibility code | LC1F |