Technical data
Differential Pressure - Piezoresistive
| Measuring range |
-200 to 200 hPa
|
|---|---|
| Accuracy |
±1.5 % of mv (Remaining Range)
±0.5 hPa (-49.9 to 49.9 hPa)
|
| Resolution |
0.1 hPa
|
Absolute Pressure
| Measuring range |
+600 to +1150 hPa
|
|---|---|
| Accuracy |
±10 hPa
|
| Resolution |
1 hPa
|
Flue gas O₂
| Measuring range |
0 to 25 Vol.%
|
|---|---|
| Accuracy |
±0.2 Vol.%
|
| Resolution |
0.01 Vol.%
|
| Reaction time t₉₀ |
< 20 s
|